Oil-in-Water Sensor
HydroMetric oil-in-water sensor for continuous monitoring of mineral oil contamination in industrial wastewater and environmental waters. The optical measurement uses UV fluorescence, providing reagent-free operation, short response time and continuous online measurement.
Technical Specifications
| Measurement principle | UV fluorescence |
|---|---|
| Measurement range | 0–50 mg/L (NDSA) |
| Accuracy | ±10% of measured value or ±0.3 mg/L, whichever is greater |
| Repeatability | ±5% |
| Resolution | 0.01 mg/L |
| Pressure range | ≤0.4 MPa |
| Calibration | Sample calibration and slope calibration |
| Sensor body | SUS316L standard; titanium alloy option for seawater |
| Cable | PUR; 10 m standard, extendable to 100 m |
| Communication | MODBUS RS485 |
| Analog output | 3 × 4–20 mA |
| Relay output | 3 programmable relays |
| Power supply | 85–500 VAC or 9–36 VDC |
| Operating temperature | 0–45°C, non-freezing |
| Storage temperature | -15–50°C |
| Sensor dimensions | Ø60 × 262 mm |
| Sensor weight | Approx. 2.1 kg |
| Protection | Sensor IP68 / NEMA 6P; transmitter IP66 / NEMA 4X |
| Cleaning | Automatic scraper cleaning |
Applications
Suitable for real-time oil-in-water monitoring in petroleum and chemical wastewater, power-industry water systems, industrial discharge outlets, surface water, groundwater, seawater and drinking-water source monitoring. The method is intended primarily for mineral-oil measurement rather than animal or vegetable oils.
Installation & Integration
Specify the water matrix, expected oil range, immersion or flow-cell arrangement, material requirement, cable length, power supply and control interface when requesting a quotation. For saline or corrosive service, request the titanium version where appropriate.
Request a Quote
Contact HydroMetric with the application, expected concentration range and installation conditions for configuration guidance and B2B quotation. Email sales@waterqualityanalyzer.com.