Online Residual & Total Chlorine Analyzer
Online DPD colorimetric analyzer for residual or total chlorine measurement in treated-water systems, with automatic cleaning, touchscreen operation and analog/digital communications.
Technical Specifications
| Measurement principle | DPD colorimetry |
|---|---|
| Parameters | Residual chlorine or total chlorine |
| Measurement range | Residual chlorine: 0–10 mg/L; total chlorine: 0–10 or 0–20 mg/L |
| Display | 7-inch touchscreen |
| Reagent life | About 30 days on recycle basis |
| Cleaning | Automatic cleaning |
| Data | Internal storage with SD export |
| Alarms | Reagent shortage alarm |
| Measurement mode | Continuous or periodic |
| Power | AC220V or DC24V |
| Interfaces | External trigger, relay output, 4–20 mA and Modbus RS485 |
Applications
Drinking water, disinfection process monitoring and treated-water systems requiring automated chlorine analysis.
Selection & Integration
Confirm whether residual or total chlorine is required, sample conditions, measuring cycle, power supply and communication interface.